Overview
Max Energy [kWh]
20
Energy, 90% DoD [kWh] 1
18
Energy, 80% DoD [kWh] 1
16
Nominal Voltage [V] 2
204
Max/Min Operating Voltage [V]
227/182
Max/Cont Discharge Current [A]
150/80
Max/Cont Discharge Power [kW]
30/16
Max and Cont Charge Current [A]
100
Weight [kg]
173
Dimensions on or against wall excluding protuberances such as glands and breaker handle -Height x Width x Depth [mm]
745x640x290
DC Connection – Fly Leads, [no. per electrode] 3
1 x 16mm2
External Interfacing
CAN Bus
Enclosure
Aluminium – powder coated white, IP54 enclosure rating, Home – wall or floor mount, Business – floor mount
Protection
Shunt Trip Circuit Breaker sized to suit max current, can be tripped by BMS if critical fault incl. overcurrent,
cell under and over voltage, temperature, weak cell detection, minimum SOC control, manual reset
Human Interface
State of Charge Display (0 to 100%), Error light, Error Reset Button, USB Plug for Programming
Service Life 4
10 year (or 4000 cycles) warranty for 80% average DoD, 13-15 yrs (>5 500 cycles) expected life at 70% DoD, 15-20 years at 50% DoD (>7 000 cycles)